About New Kirloskar Generator
Kirloskar Silent & Open DieselGenerators
PowerRange:5 kVA to 3000 kVA
Phase:Single & Three Phase
Countryof Origin: Made in India
Product Overview
Experienceuninterrupted power and trusted performance with KirloskarDiesel Generators Indias most reliable and efficient powersolutions.
KirloskarSilent Generators are equipped with acoustic enclosures for noise-freeoperation, while Open Type Generators are designed for heavy-duty industrialapplications.
Whether for home backup or commercial power, Kirloskar gensets ensure stablevoltage, consistent frequency, and long-lasting durability maximizing uptimeand protecting your equipment.
Key Features & Benefits
- High Reliability: Powered by robust Kirloskar engines engineered for long life andconsistent performance.
- Silent Operation: Acoustic canopy meets CPCB IV+ standards for low noise levels.
- Fuel Efficiency: Advanced fuel injection system minimizes fuel consumption andmaximizes savings.
- Heavy-Duty Design: Strong alternators, anti-vibration mounts, and durableconstruction for long-term performance.
- Smart Control Options: Available with Manual, AMF (AutoMains Failure), and Remote Monitoring systems.
- Eco-Friendly: CPCB IV+ compliant engines ensure low emissions and cleanerperformance.
- Easy Portability: Compact canopy with lifting hooks, skid base, and simple mobilityoptions.
- Advanced Safety Features: Includes oil pressure sensor,water temperature indicator, circuit breaker, and emergency stop function.
Applications: Ideal forhomes, offices, hospitals, industries, showrooms, construction sites, andagricultural use.
Available Models & Applications
KirloskarSilent Diesel Generators (With Acoustic Enclosure)
- 15 kVA Silent DG Set: Compact model for homes, shops,and small offices.
- 25 kVA to 62.5 kVA: Suitable for showrooms, schools, clinics, and small industries.
- 82.5 kVA to 125 kVA: Ideal for mid-sized businesses, hotels, and commercial complexes.
- 160 kVA to 250 kVA: Perfect for large offices, hospitals, and manufacturing units.
- 320 kVA to 500 kVA: Reliable power for factories and infrastructure projects.
- 600 kVA to 1010 kVA: Heavy-duty models for data centres, large industries, andinstitutions.
Kirloskar Open Type Diesel Generators
15 kVA to 250 kVA: Cost-effective, easy-maintenance gensets for industrial andconstruction applications.
Technical Highlights
| Specification | Details |
| Engine Type | Kirloskar CPCB IV+ Compliant Diesel Engine |
| Starting System | Manual / Electric Start / AMF Panel |
| Cooling System | Water-Cooled / Air-Cooled (as per model) |
| Alternator Type | Brushless, Self-Excited, High Efficiency |
| Frequency | 50 Hz / 60 Hz |
| Voltage | 230V (Single Phase) / 415V (Three Phase) |
| Insulation Class | H Class (High Protection) |
| Canopy Design | Powder-Coated, Weather & Sound Proof |
| Fuel Tank Capacity | Long-run diesel tank for extended backup |
| Warranty | 1 Year on DG Set / 2 Years on Engine (model-based) |
Why Choose Kirloskar Generators?
- India leading and trusted generator brand.
- Low maintenance with nationwide service support.
- Superior fuel efficiency for maximum cost savings.
- Environment-friendly design with low noise and emissions.
- Built for 24x7 continuous heavy-duty operation.
- Ready stock available with fast delivery and installation acrossIndia.
Why Choose KY Enterprise?
- Authorized and experienced Kirloskar & Cummins supplier.
- Quick response and prompt after-sales support.
- Wide range of genuine engines, gensets, and spare parts.
- Customer-focused approach ensuring complete satisfaction.
Contact Us
Forquotations, product catalogues, and expert guidance:
Mobile:+91 6352073591 (WhatsApp available)
Email:chirag@kyenterprise.com
KYEnterprise: Powering Performance withGenuine Kirloskar Solutions.
Advanced Digital Controls and Operator SafetyThis Kirloskar generator is equipped with a microprocessor-based controller panel, ensuring precise operation and automation. The panel supports AMF compatibility and incorporates digital display features for clear monitoring of parameters. Built-in safety functions, such as automatic shutdown on low oil pressure and high temperature, safeguard the engine and provide peace of mind.
Engineered for Efficiency and DurabilityPowered by the Kirloskar HA294 engine, this 4-stroke, naturally aspirated generator delivers consistent output with excellent fuel efficiency-consuming just 3.5 L/h at 75% load. Its high-grade steel sound-proof canopy offers weather resistance and superior noise reduction, maintaining compliance with CPCB II norms. Maintenance is straightforward with wide-access doors.
Flexible and Reliable Power DeliveryThe generator operates at 1500 RPM, producing 20 kVA at 415V in three-phase AC, making it suitable for diverse installations. Electric start, IP23 protection class, and brushless self-excited alternator ensure reliable performance, while a sizable 65-litre fuel tank supports extended runtime without frequent refuelling.
FAQ's of New Kirloskar Generator:
Q: How does the microprocessor-based controller panel enhance generator operation?
A: The microprocessor-based controller panel offers automated control, precise monitoring of generator parameters via a digital display, and AMF compatibility for seamless mains-failure standby operation. This automation ensures optimal performance and ease of use, reducing the need for manual intervention.
Q: What safety features are included in the Kirloskar generator?
A: The generator includes critical safety mechanisms such as automatic shutdown in cases of low oil pressure and high engine temperature, protecting both the engine and users from potential damage or hazards. These features help maintain reliable performance and equipment longevity.
Q: Where can this generator be used given its enclosure and weather resistance?
A: With a sound-proof, weather-resistant high-grade steel canopy and compliance with CPCB II emission and noise norms, this generator is suitable for outdoor and indoor installations across industrial, commercial, and institutional settings, particularly in regions with variable weather conditions.
Q: When is generator maintenance required and how is it facilitated?
A: Routine maintenance should be conducted according to the manufacturer's guidelines, typically after a set number of operating hours or as indicated by the hour meter. Wide service doors on the canopy provide easy access for inspections, lubricating oil checks, and routine upkeep, making the process straightforward.
Q: What are the usage benefits of the AVR-controlled voltage regulation?
A: AVR (Automatic Voltage Regulator) ensures steady voltage output with only a 1% variation, protecting sensitive electrical equipment from fluctuations and improving overall power quality. This is particularly advantageous for applications requiring stable and reliable electricity supply.
Q: How is the generator started and what power output can be expected?
A: The generator features an electric start system for user convenience. It provides a rated power output of 20 kVA at 415V (three-phase), suitable for a range of industrial and commercial power requirements.
Q: What process should be followed if the generator shuts down unexpectedly?
A: If the generator shuts down unexpectedly, check the digital display for alerts indicating possible causes such as low oil pressure or high temperature. Address the issues-top up oil or allow cooling as needed-before attempting a restart, following the manufacturer's safety instructions.