About 160 Kva Kirloskar Generator
PowerRange:5 kVA to 3000 kVA
Phase:Single & Three Phase
Countryof Origin: Made in India
Product Overview
Experienceuninterrupted power and trusted performance with KirloskarDiesel Generators Indias most reliable and efficient powersolutions.
KirloskarSilent Generators are equipped with acoustic enclosures for noise-freeoperation, while Open Type Generators are designed for heavy-duty industrialapplications.
Whether for home backup or commercial power, Kirloskar gensets ensure stablevoltage, consistent frequency, and long-lasting durability maximizing uptimeand protecting your equipment.
Key Features & Benefits
· Powered by robust Kirloskar engines engineered for long life andconsistent performance.
· Acoustic canopy meets CPCB IV+ standards for low noise levels.
· Advanced fuel injection system minimizes fuel consumption andmaximizes savings.
· Strong alternators, anti-vibration mounts, and durableconstruction for long-term performance.
· Available with Manual, AMF (AutoMains Failure), and Remote Monitoring systems.
· CPCB IV+ compliant engines ensure low emissions and cleanerperformance.
· Compact canopy with lifting hooks, skid base, and simple mobilityoptions.
· Includes oil pressure sensor,water temperature indicator, circuit breaker, and emergency stop function.
Applications: Ideal forhomes, offices, hospitals, industries, showrooms, construction sites, andagricultural use.
Available Models & Applications
KirloskarSilent Diesel Generators (With Acoustic Enclosure)
· Compact model for homes, shops,and small offices.
· Suitable for showrooms, schools, clinics, and small industries.
· Ideal for mid-sized businesses, hotels, and commercial complexes.
· Perfect for large offices, hospitals, and manufacturing units.
· Reliable power for factories and infrastructure projects.
· Heavy-duty models for data centres, large industries, andinstitutions.
Kirloskar Open Type Diesel Generators
15 kVA to 250 kVA: Cost-effective, easy-maintenance gensets for industrial andconstruction applications.
Technical Highlights
| Specification | Details |
| Engine Type | Kirloskar CPCB IV+ Compliant Diesel Engine |
| Starting System | Manual / Electric Start / AMF Panel |
| Cooling System | Water-Cooled / Air-Cooled (as per model) |
| Alternator Type | Brushless, Self-Excited, High Efficiency |
| Frequency | 50 Hz / 60 Hz |
| Voltage | 230V (Single Phase) / 415V (Three Phase) |
| Insulation Class | H Class (High Protection) |
| Canopy Design | Powder-Coated, Weather & Sound Proof |
| Fuel Tank Capacity | Long-run diesel tank for extended backup |
| Warranty | 1 Year on DG Set / 2 Years on Engine (model-based) |
Why Choose Kirloskar Generators?
· · · · · · Why Choose KY Enterprise?
· · · · Customer-focused approach ensuring complete satisfaction.
Contact Us
Forquotations, product catalogues, and expert guidance:
Mobile:+91 6352073591 (WhatsApp available)
Email:chirag@kyenterprise.com
KYEnterprise: Powering Performance withGenuine Kirloskar Solutions.
Keywords: KirloskarGenerator, Kirloskar Diesel Generator, Kirloskar Silent Generator, Kirloskar DGSet, Kirloskar Open Type Generator, 15 kVA Kirloskar Generator, 62.5 kVA DGSet, 125 kVA Kirloskar Genset, Kirloskar CPCB IV+ Generator, KirloskarIndustrial Generator, Kirloskar Commercial Generator, Kirloskar Diesel GensetPrice, Kirloskar Generator Dealer in India, Kirloskar Generator Supplier,Kirloskar Generator with Canopy, Kirloskar AMF Panel Generator, Kirloskar OpenDiesel Generator.
Advanced Microprocessor-Based ControlThe integrated AMF panel ensures automatic changeover between mains power and generator, enabling seamless, uninterrupted operation during power failures. Managed by a reliable microprocessor-based controller, this system offers precise voltage (1%) and frequency (0.5%) regulation, enhancing operational stability and equipment safety. Real-time monitoring and event logging simplify diagnostics and maintenance.
Superior Engine Performance and EfficiencyThe Kirloskar 6R1080TA diesel engine delivers robust 160 kVA output, optimized by electronic governing and brushless AVR alternator technology. Designed for continuous duty (S1), it offers consistent performance even in elevated ambient conditions up to 50C and at altitudes above 1000m with deration. An efficient cooling system ensures durability, while a 250-liter fuel tank supports extended operation.
Comprehensive Safety and Compliance FeaturesThis generator boasts comprehensive safeguards, including mechanisms against low oil pressure, high coolant temperature, overspeed, overload, and short-circuit. It complies with stringent CPCB II emission norms, ensuring environmentally responsible performance. Class H insulation and IP23 protection further improve reliability and safe operation in varied industrial settings.
FAQ's of 160 Kva Kirloskar Generator:
Q: How does the auto mains failure (AMF) panel work in the Kirloskar 160 kVA generator?
A: The AMF panel automatically detects mains power failure and seamlessly switches power supply to the generator. When the mains supply is restored, it safely transfers the load back and shuts down the generator, eliminating manual intervention for uninterrupted power.
Q: What are the benefits of the electronic governor and brushless AVR in this generator?
A: The electronic governor provides precise engine speed control for stable output, while the brushless AVR maintains voltage within 1%. Together, they deliver consistent performance, protect sensitive equipment, and reduce wear, supporting long-term operational efficiency.
Q: When is altitude deration required for this generator, and how does it impact performance?
A: Altitude deration applies when the generator operates above 1000 meters. At higher elevations, air density reduces engine power output, so adjustments may be necessary to maintain performance and prevent overloading. Consult the manufacturer's guidelines for specific deration factors.
Q: Where can the 160 kVA Kirloskar Generator be installed for optimal use?
A: This generator is suitable for industrial, commercial, and critical facilities across India. It should be installed on a stable, well-ventilated area, protected from extreme weather, and comply with local safety, noise, and emission regulations for best performance and safety.
Q: What is the process for routine maintenance of this generator?
A: Routine maintenance involves checking oil and coolant levels, inspecting filters, examining the fuel system, testing the battery, and running periodic generator load tests. Regularly following the manufacturer's service intervals ensures reliable performance and prolongs equipment life.
Q: How is the generator started, and what is the battery specification?
A: The generator employs an electric start system, powered by two 12V, 100Ah batteries. This arrangement ensures dependable and quick engine starting, even under demanding conditions.
Q: What are the primary benefits of using this generator for continuous duty operations?
A: Its robust design, continuous duty rating (S1), and compliance with ISO 8528 and CPCB II standards enable reliable, safe, and efficient operation, making it ideal for round-the-clock power supply needs in challenging environments.