About 125 Kva Koel Generator
PowerRange:5 kVA to 3000 kVA
Phase:Single & Three Phase
Countryof Origin: Made in India
Product Overview
Experienceuninterrupted power and trusted performance with KirloskarDiesel Generators Indias most reliable and efficient powersolutions.
KirloskarSilent Generators are equipped with acoustic enclosures for noise-freeoperation, while Open Type Generators are designed for heavy-duty industrialapplications.
Whether for home backup or commercial power, Kirloskar gensets ensure stablevoltage, consistent frequency, and long-lasting durability maximizing uptimeand protecting your equipment.
Key Features & Benefits
· Powered by robust Kirloskar engines engineered for long life andconsistent performance.
· Acoustic canopy meets CPCB IV+ standards for low noise levels.
· Advanced fuel injection system minimizes fuel consumption andmaximizes savings.
· Strong alternators, anti-vibration mounts, and durableconstruction for long-term performance.
· Available with Manual, AMF (AutoMains Failure), and Remote Monitoring systems.
· CPCB IV+ compliant engines ensure low emissions and cleanerperformance.
· Compact canopy with lifting hooks, skid base, and simple mobilityoptions.
· Includes oil pressure sensor,water temperature indicator, circuit breaker, and emergency stop function.
Applications: Ideal forhomes, offices, hospitals, industries, showrooms, construction sites, andagricultural use.
Available Models & Applications
KirloskarSilent Diesel Generators (With Acoustic Enclosure)
· Compact model for homes, shops,and small offices.
· Suitable for showrooms, schools, clinics, and small industries.
· Ideal for mid-sized businesses, hotels, and commercial complexes.
· Perfect for large offices, hospitals, and manufacturing units.
· Reliable power for factories and infrastructure projects.
· Heavy-duty models for data centres, large industries, andinstitutions.
Kirloskar Open Type Diesel Generators
15 kVA to 250 kVA: Cost-effective, easy-maintenance gensets for industrial andconstruction applications.
Technical Highlights
| Specification | Details |
| Engine Type | Kirloskar CPCB IV+ Compliant Diesel Engine |
| Starting System | Manual / Electric Start / AMF Panel |
| Cooling System | Water-Cooled / Air-Cooled (as per model) |
| Alternator Type | Brushless, Self-Excited, High Efficiency |
| Frequency | 50 Hz / 60 Hz |
| Voltage | 230V (Single Phase) / 415V (Three Phase) |
| Insulation Class | H Class (High Protection) |
| Canopy Design | Powder-Coated, Weather & Sound Proof |
| Fuel Tank Capacity | Long-run diesel tank for extended backup |
| Warranty | 1 Year on DG Set / 2 Years on Engine (model-based) |
Why Choose Kirloskar Generators?
· · · · · · Why Choose KY Enterprise?
· · · · Customer-focused approach ensuring complete satisfaction.
Contact Us
Forquotations, product catalogues, and expert guidance:
Mobile:+91 6352073591 (WhatsApp available)
Email:chirag@kyenterprise.com
KYEnterprise: Powering Performance withGenuine Kirloskar Solutions.
Keywords: KirloskarGenerator, Kirloskar Diesel Generator, Kirloskar Silent Generator, Kirloskar DGSet, Kirloskar Open Type Generator, 15 kVA Kirloskar Generator, 62.5 kVA DGSet, 125 kVA Kirloskar Genset, Kirloskar CPCB IV+ Generator, KirloskarIndustrial Generator, Kirloskar Commercial Generator, Kirloskar Diesel GensetPrice, Kirloskar Generator Dealer in India, Kirloskar Generator Supplier,Kirloskar Generator with Canopy, Kirloskar AMF Panel Generator, Kirloskar OpenDiesel Generator.
Advanced Fully Automatic Microprocessor ControlThe generator is equipped with a microprocessor-based, fully automatic control system, simplifying operations and enhancing reliability. This controller allows for seamless start-stop functionality, precise monitoring, and comprehensive safety features, ensuring uninterrupted power supply for critical installations.
Superior Voltage and Frequency StabilityThanks to its electronic AVR, the generator delivers voltage regulation within 1% and frequency regulation within 1.5%. This high level of stability protects sensitive equipment and supports consistent performance during fluctuating loads.
Silent, Reliable Operation and Sturdy ConstructionEncased in a standard sound-proof acoustic enclosure, the 125 KVA KOEL generator operates quietly, compliant with CPCB noise standards. With a strong base-frame mounted design and water-cooling system, it can handle ambient temperatures up to 50C, offering reliability in challenging conditions.
FAQ's of 125 Kva Koel Generator:
Q: How does the fully automatic microprocessor controller benefit this generator's operation?
A: The microprocessor-based, fully automatic controller manages the generator's startup, shutdown, and safety checks without manual intervention. It enhances reliability, minimizes human error, and streamlines monitoring, making it ideal for critical or unattended installations.
Q: What is the process for starting the generator and how quickly does it supply power?
A: The electric start feature allows for quick and effortless generator activation. Once started, the generator automatically synchronizes and supplies power at rated voltage (415V) and frequency (50 Hz) within seconds, ensuring minimal downtime during power outages.
Q: When should I perform maintenance, and what are the key service points?
A: Routine maintenance is recommended every 250 hours of operation or as specified in the manufacturer's manual. Key service points include checking the lubrication oil (20 litres capacity), inspecting the cooling system, cleaning filters, and ensuring the battery (12V, 135Ah) is in good condition.
Q: Where can this generator be installed, and what are its mounting requirements?
A: The generator is designed for base frame mounting and is suitable for both indoor and outdoor installations, provided there is adequate ventilation and clearance for maintenance. Its acoustic enclosure allows operation in noise-sensitive environments as per CPCB norms.
Q: What advantages do the electronic AVR and Class H insulation provide?
A: The electronic AVR maintains voltage within 1%, protecting equipment from fluctuations, while Class H insulation ensures greater thermal stability, extending the lifespan of both the alternator and the generator during heavy or prolonged usage.
Q: How does the generator perform during overload and extreme temperatures?
A: This model offers an overload capacity of 110% for one hour every twelve hours of operation, and can operate reliably in ambient temperatures up to 50C, ensuring consistent power even in demanding conditions.
Q: What are the main benefits of the KOEL 6SL908TA-G1 engine in this generator?
A: The 6-cylinder, turbocharged, water-cooled diesel engine provides high fuel efficiency (24.2L/hr at full load), robust performance, and durability. Its advanced design reduces emissions (CPCB II compliant) and offers a high compression ratio (17.5:1) for optimal power output.