About Kirloskar Green Generator
PowerRange:5 kVA to 3000 kVA
Phase:Single & Three Phase
Countryof Origin: Made in India
Product Overview
Experienceuninterrupted power and trusted performance with KirloskarDiesel Generators Indias most reliable and efficient powersolutions.
KirloskarSilent Generators are equipped with acoustic enclosures for noise-freeoperation, while Open Type Generators are designed for heavy-duty industrialapplications.
Whether for home backup or commercial power, Kirloskar gensets ensure stablevoltage, consistent frequency, and long-lasting durability maximizing uptimeand protecting your equipment.
Key Features & Benefits
· Powered by robust Kirloskar engines engineered for long life andconsistent performance.
· Acoustic canopy meets CPCB IV+ standards for low noise levels.
· Advanced fuel injection system minimizes fuel consumption andmaximizes savings.
· Strong alternators, anti-vibration mounts, and durableconstruction for long-term performance.
· Available with Manual, AMF (AutoMains Failure), and Remote Monitoring systems.
· CPCB IV+ compliant engines ensure low emissions and cleanerperformance.
· Compact canopy with lifting hooks, skid base, and simple mobilityoptions.
· Includes oil pressure sensor,water temperature indicator, circuit breaker, and emergency stop function.
Applications: Ideal forhomes, offices, hospitals, industries, showrooms, construction sites, andagricultural use.
Available Models & Applications
KirloskarSilent Diesel Generators (With Acoustic Enclosure)
· Compact model for homes, shops,and small offices.
· Suitable for showrooms, schools, clinics, and small industries.
· Ideal for mid-sized businesses, hotels, and commercial complexes.
· Perfect for large offices, hospitals, and manufacturing units.
· Reliable power for factories and infrastructure projects.
· Heavy-duty models for data centres, large industries, andinstitutions.
Kirloskar Open Type Diesel Generators
15 kVA to 250 kVA: Cost-effective, easy-maintenance gensets for industrial andconstruction applications.
Technical Highlights
| Specification | Details |
| Engine Type | Kirloskar CPCB IV+ Compliant Diesel Engine |
| Starting System | Manual / Electric Start / AMF Panel |
| Cooling System | Water-Cooled / Air-Cooled (as per model) |
| Alternator Type | Brushless, Self-Excited, High Efficiency |
| Frequency | 50 Hz / 60 Hz |
| Voltage | 230V (Single Phase) / 415V (Three Phase) |
| Insulation Class | H Class (High Protection) |
| Canopy Design | Powder-Coated, Weather & Sound Proof |
| Fuel Tank Capacity | Long-run diesel tank for extended backup |
| Warranty | 1 Year on DG Set / 2 Years on Engine (model-based) |
Why Choose Kirloskar Generators?
· · · · · · Why Choose KY Enterprise?
· · · · Customer-focused approach ensuring complete satisfaction.
Contact Us
Forquotations, product catalogues, and expert guidance:
Mobile:+91 6352073591 (WhatsApp available)
Email:chirag@kyenterprise.com
KYEnterprise: Powering Performance withGenuine Kirloskar Solutions.
Keywords: KirloskarGenerator, Kirloskar Diesel Generator, Kirloskar Silent Generator, Kirloskar DGSet, Kirloskar Open Type Generator, 15 kVA Kirloskar Generator, 62.5 kVA DGSet, 125 kVA Kirloskar Genset, Kirloskar CPCB IV+ Generator, KirloskarIndustrial Generator, Kirloskar Commercial Generator, Kirloskar Diesel GensetPrice, Kirloskar Generator Dealer in India, Kirloskar Generator Supplier,Kirloskar Generator with Canopy, Kirloskar AMF Panel Generator, Kirloskar OpenDiesel Generator.
Advanced Microprocessor-Based ControlThe Kirloskar Green Generator is equipped with a state-of-the-art microprocessor-based genset controller that enables precise monitoring and efficient management of generator functions. This advanced controller provides automatic start/stop capabilities, safeguarding your operations through reliable protection features while supporting ease of use for operators.
Reliable Performance in Harsh ConditionsDesigned to withstand India's demanding environments, this generator operates effectively at ambient temperatures up to 50C and relative humidity as high as 90% (non-condensing). The water-cooled, turbocharged engine ensures stable performance, making it an ideal choice for a wide range of industries and climatic conditions.
Fuel Efficiency and Extended RuntimeWith a fuel consumption rate of 12.9 litres per hour at full load and a large 150-litre fuel tank, the generator offers extended runtime and reduced refuelling frequency. This efficiency not only translates to lower operating costs but also ensures uninterrupted power supply during critical operations.
FAQ's of Kirloskar Green Generator:
Q: How does the microprocessor-based genset controller enhance generator operation?
A: The microprocessor-based genset controller offers automatic control, real-time monitoring, and fault protection. It improves user experience by providing clear status updates, efficient troubleshooting, and seamless integration with modern power systems.
Q: What benefits does the Kirloskar Green Generator's water-cooled engine provide?
A: The water-cooled engine maintains optimal temperature even under heavy load or high ambient conditions, reducing the risk of overheating and extending engine life. This ensures continuous operation with minimal maintenance interruptions.
Q: Where is the Kirloskar Green Generator best suited for use?
A: This generator is suitable for a variety of environments-industrial complexes, commercial sites, construction projects, and service industries-thanks to its silent operation, robust build, and ability to perform in extreme weather conditions across India.
Q: What is the standard process for starting and operating this generator?
A: The generator features electric starting for ease of use. To operate, simply engage the electric start system, and the microprocessor-based controller manages the rest, including load regulation and safety features.
Q: When should routine maintenance be performed on the generator?
A: Regular maintenance, such as oil checks, filter replacements, and system inspections, should be conducted according to the manufacturer's recommended schedule or after every significant run period, ensuring optimal performance and longevity.
Q: How does conformity to CPCB II emission norms benefit users?
A: Compliance with CPCB II emission norms means the generator releases fewer pollutants, ensuring environmentally responsible operation and adherence to Indian regulatory standards. This reduces environmental impact and potential legal concerns.
Q: What measures are taken to ensure safe operation in high humidity or temperature?
A: With design specifications catering to up to 50C ambient temperature and 90% non-condensing relative humidity, the generator incorporates advanced cooling and weather-resistant elements, ensuring safe, reliable operation in challenging environments.