About 250 Kva Kirloskar Generator
PowerRange:5 kVA to 3000 kVA
Phase:Single & Three Phase
Countryof Origin: Made in India
Product Overview
Experienceuninterrupted power and trusted performance with KirloskarDiesel Generators Indias most reliable and efficient powersolutions.
KirloskarSilent Generators are equipped with acoustic enclosures for noise-freeoperation, while Open Type Generators are designed for heavy-duty industrialapplications.
Whether for home backup or commercial power, Kirloskar gensets ensure stablevoltage, consistent frequency, and long-lasting durability maximizing uptimeand protecting your equipment.
Key Features & Benefits
· Powered by robust Kirloskar engines engineered for long life andconsistent performance.
· Acoustic canopy meets CPCB IV+ standards for low noise levels.
· Advanced fuel injection system minimizes fuel consumption andmaximizes savings.
· Strong alternators, anti-vibration mounts, and durableconstruction for long-term performance.
· Available with Manual, AMF (AutoMains Failure), and Remote Monitoring systems.
· CPCB IV+ compliant engines ensure low emissions and cleanerperformance.
· Compact canopy with lifting hooks, skid base, and simple mobilityoptions.
· Includes oil pressure sensor,water temperature indicator, circuit breaker, and emergency stop function.
Applications: Ideal forhomes, offices, hospitals, industries, showrooms, construction sites, andagricultural use.
Available Models & Applications
KirloskarSilent Diesel Generators (With Acoustic Enclosure)
· Compact model for homes, shops,and small offices.
· Suitable for showrooms, schools, clinics, and small industries.
· Ideal for mid-sized businesses, hotels, and commercial complexes.
· Perfect for large offices, hospitals, and manufacturing units.
· Reliable power for factories and infrastructure projects.
· Heavy-duty models for data centres, large industries, andinstitutions.
Kirloskar Open Type Diesel Generators
15 kVA to 250 kVA: Cost-effective, easy-maintenance gensets for industrial andconstruction applications.
Technical Highlights
| Specification | Details |
| Engine Type | Kirloskar CPCB IV+ Compliant Diesel Engine |
| Starting System | Manual / Electric Start / AMF Panel |
| Cooling System | Water-Cooled / Air-Cooled (as per model) |
| Alternator Type | Brushless, Self-Excited, High Efficiency |
| Frequency | 50 Hz / 60 Hz |
| Voltage | 230V (Single Phase) / 415V (Three Phase) |
| Insulation Class | H Class (High Protection) |
| Canopy Design | Powder-Coated, Weather & Sound Proof |
| Fuel Tank Capacity | Long-run diesel tank for extended backup |
| Warranty | 1 Year on DG Set / 2 Years on Engine (model-based) |
Why Choose Kirloskar Generators?
· · · · · · Why Choose KY Enterprise?
· · · · Customer-focused approach ensuring complete satisfaction.
Contact Us
Forquotations, product catalogues, and expert guidance:
Mobile:+91 6352073591 (WhatsApp available)
Email:chirag@kyenterprise.com
KYEnterprise: Powering Performance withGenuine Kirloskar Solutions.
Keywords: KirloskarGenerator, Kirloskar Diesel Generator, Kirloskar Silent Generator, Kirloskar DGSet, Kirloskar Open Type Generator, 15 kVA Kirloskar Generator, 62.5 kVA DGSet, 125 kVA Kirloskar Genset, Kirloskar CPCB IV+ Generator, KirloskarIndustrial Generator, Kirloskar Commercial Generator, Kirloskar Diesel GensetPrice, Kirloskar Generator Dealer in India, Kirloskar Generator Supplier,Kirloskar Generator with Canopy, Kirloskar AMF Panel Generator, Kirloskar OpenDiesel Generator.
Advanced Engine Technology for Reliable PerformancePowered by a Kirloskar 6R1080TAG2 engine, this generator combines a 6-cylinder, turbocharged, aftercooled design for high efficiency and durability. It delivers 250 kVA of stable power output at 415V, ensuring smooth operation for factories, construction sites, and business establishments where uninterrupted power is mission-critical.
Smart Controls and MonitoringEquipped with an automatic control panel featuring AMF (Auto Mains Failure) and digital monitoring display, users benefit from precise operational data and quick response to power interruptions. The system simplifies management and guarantees prompt switching to generator power in the event of grid failures.
Built for Challenging EnvironmentsThe generator is engineered to operate effortlessly in high temperatures (up to 50C) and altitudes up to 1000 meters without derating. Its protection class IP23 enclosure, efficient fuel consumption of approximately 47-52 liters per hour at full load, and sound-attenuated design make it suitable for use across diverse Indian terrains.
FAQ's of 250 Kva Kirloskar Generator:
Q: How does the automatic control panel with AMF benefit users of the 250 KVA Kirloskar Generator?
A: The automatic control panel with AMF (Auto Mains Failure) detects grid power loss and automatically starts the generator, ensuring seamless power continuity. This feature minimizes downtime and manual intervention, especially valuable in critical operations.
Q: What is the typical fuel consumption of this generator at full load usage?
A: At 100% load, the 250 KVA Kirloskar Generator consumes approximately 47-52 liters of HSD (High Speed Diesel) per hour, optimizing fuel efficiency for long-duration operations.
Q: When should routine maintenance be performed on this generator set?
A: Routine maintenance, such as checking lubrication, coolant levels, battery condition, and filter cleaning, should be performed as per the manufacturer's recommended schedule-usually after every 250-300 hours of operation or monthly, whichever comes first.
Q: Where is this generator suitable for installation?
A: Owing to its water-cooled system, low noise levels, and robust design, this generator is suitable for commercial complexes, industrial sites, hospitals, and construction projects, even in environments with ambient temperatures up to 50C and altitudes up to 1000 meters.
Q: What process controls are available with the digital monitoring panel?
A: The digital monitoring panel provides real-time data on voltage, current, frequency, fuel levels, battery status, and engine parameters, allowing users to oversee operational health and address issues proactively.
Q: Can the generator handle short-term overloads?
A: Yes, the generator is designed with an overload capacity of up to 110% of its rated load for one hour, supporting temporary increases in power demand without compromising performance or safety.
Q: What are the key benefits of using a brushless alternator in this system?
A: The brushless alternator demands less maintenance, offers greater reliability, and ensures stable AC three-phase output, which is essential for powering sensitive equipment and industrial loads.