About 15 Kva Kirloskar Generator
Kirloskar Silent & Open DieselGenerators
PowerRange:5 kVA to 3000 kVA
Phase:Single & Three Phase
Countryof Origin: Made in India
Product Overview
Experienceuninterrupted power and trusted performance with KirloskarDiesel Generators Indias most reliable and efficient powersolutions.
KirloskarSilent Generators are equipped with acoustic enclosures for noise-freeoperation, while Open Type Generators are designed for heavy-duty industrialapplications.
Whether for home backup or commercial power, Kirloskar gensets ensure stablevoltage, consistent frequency, and long-lasting durability maximizing uptimeand protecting your equipment.
Key Features & Benefits
- High Reliability: Powered by robust Kirloskar engines engineered for long life andconsistent performance.
- Silent Operation: Acoustic canopy meets CPCB IV+ standards for low noise levels.
- Fuel Efficiency: Advanced fuel injection system minimizes fuel consumption andmaximizes savings.
- Heavy-Duty Design: Strong alternators, anti-vibration mounts, and durableconstruction for long-term performance.
- Smart Control Options: Available with Manual, AMF (AutoMains Failure), and Remote Monitoring systems.
- Eco-Friendly: CPCB IV+ compliant engines ensure low emissions and cleanerperformance.
- Easy Portability: Compact canopy with lifting hooks, skid base, and simple mobilityoptions.
- Advanced Safety Features: Includes oil pressure sensor,water temperature indicator, circuit breaker, and emergency stop function.
Applications: Ideal forhomes, offices, hospitals, industries, showrooms, construction sites, andagricultural use.
Available Models & Applications
KirloskarSilent Diesel Generators (With Acoustic Enclosure)
- 15 kVA Silent DG Set: Compact model for homes, shops,and small offices.
- 25 kVA to 62.5 kVA: Suitable for showrooms, schools, clinics, and small industries.
- 82.5 kVA to 125 kVA: Ideal for mid-sized businesses, hotels, and commercial complexes.
- 160 kVA to 250 kVA: Perfect for large offices, hospitals, and manufacturing units.
- 320 kVA to 500 kVA: Reliable power for factories and infrastructure projects.
- 600 kVA to 1010 kVA: Heavy-duty models for data centres, large industries, andinstitutions.
Kirloskar Open Type Diesel Generators
15 kVA to 250 kVA: Cost-effective, easy-maintenance gensets for industrial andconstruction applications.
Technical Highlights
| Specification | Details |
| Engine Type | Kirloskar CPCB IV+ Compliant Diesel Engine |
| Starting System | Manual / Electric Start / AMF Panel |
| Cooling System | Water-Cooled / Air-Cooled (as per model) |
| Alternator Type | Brushless, Self-Excited, High Efficiency |
| Frequency | 50 Hz / 60 Hz |
| Voltage | 230V (Single Phase) / 415V (Three Phase) |
| Insulation Class | H Class (High Protection) |
| Canopy Design | Powder-Coated, Weather & Sound Proof |
| Fuel Tank Capacity | Long-run diesel tank for extended backup |
| Warranty | 1 Year on DG Set / 2 Years on Engine (model-based) |
Why Choose Kirloskar Generators?
- India leading and trusted generator brand.
- Low maintenance with nationwide service support.
- Superior fuel efficiency for maximum cost savings.
- Environment-friendly design with low noise and emissions.
- Built for 24x7 continuous heavy-duty operation.
- Ready stock available with fast delivery and installation acrossIndia.
Why Choose KY Enterprise?
- Authorized and experienced Kirloskar & Cummins supplier.
- Quick response and prompt after-sales support.
- Wide range of genuine engines, gensets, and spare parts.
- Customer-focused approach ensuring complete satisfaction.
Contact Us
Forquotations, product catalogues, and expert guidance:
Mobile:+91 6352073591 (WhatsApp available)
Email:chirag@kyenterprise.com
KYEnterprise: Powering Performance withGenuine Kirloskar Solutions.
Reliable and Efficient PerformanceWith a rated power of 15 KVA and a sturdy Stamford/Crompton alternator, this generator ensures steady power with only 1% voltage fluctuation from no load to full load. The water-cooled engine and Class H insulation provide durability and consistent functioning even in challenging conditions.
Advanced Protection and Control FeaturesThis Kirloskar generator incorporates a modern control panel, offering both automatic (AMF) and manual operation options. Built-in protection mechanisms safeguard against faults, while metering allows real-time status monitoring, ensuring operational safety and convenience.
Silent Operation and ComplianceFitted with a sound-attenuated, powder-coated canopy, the generator runs quietly at noise levels compliant with CPCB norms. Stringent emissions standards are met, making it ideal for urban, commercial, and residential applications without disturbing the surrounding environment.
FAQ's of 15 Kva Kirloskar Generator:
Q: How does the 15 KVA Kirloskar Generator ensure reliable power delivery?
A: This generator uses a highly efficient Kirloskar HA294 engine paired with a Stamford/Crompton alternator to deliver a stable 20.8 Amps at 415 V. The voltage regulation of 1% ensures consistent power from no load to full load, making it dependable for sensitive equipment and critical operations.
Q: What protection features are included in the control panel?
A: The control panel offers both automatic (AMF) and manual operation modes with built-in metering for easy monitoring. It also includes comprehensive protection mechanisms to safeguard against electrical faults and operational hazards, enhancing user safety and generator lifespan.
Q: When should I perform routine maintenance on this generator?
A: Maintenance intervals depend on usage, but it's recommended to check the oil and cooling water levels before each use and perform full inspections every 250 operating hours. Regular servicing ensures efficiency, longevity, and compliance with manufacturer guidelines.
Q: Where can I install this generator?
A: Thanks to its silent, sound-attenuated canopy and compliance with CPCB norms, the 15 KVA generator is suitable for installation in industrial plants, commercial buildings, or residential complexes where quiet operation and low emissions are required.
Q: What is the process for starting the generator?
A: The generator comes equipped with electric start functionality. Simply ensure fuel, oil, and cooling water are at recommended levels, then use the electric starter via the control panel, which provides AMF/manual operation and safety checks.
Q: How can I benefit from the generator's overload capacity?
A: The generator offers 110% overload capacity for up to 1 hour within any 12-hour period, allowing for short bursts of higher power demand without the risk of damage. This capability is useful during peak load periods in industrial and commercial applications.
Q: What are the typical applications for this generator model?
A: It is widely used for industrial operations, commercial facilities, and residential backup, providing reliable AC three-phase power in a variety of positions where continuous or emergency electricity supply is crucial.